Project: CBV Deptford Pumping Station | Requirement:Removal of D-wall and Capping Beam | Date:01/05/2022
Background
CVB required a section of D-wall and capping beam to be removed monolithically due to access constraints within the work area. Firstly, vertical separation cuts were formed, each cut containing a high density of reinforcement bar, each cut totaled 8sq.m. CVB then supported each section with a crawler crane whilst we carried out undercuts, each 3sq.m. All works were carried out using high frequency wire saws.